Investigation into negative-stiffness vibroisolation table “Minus K 500BM-1”
Abstract
The article analyzes the performance of a negative-stiffness vibroisolating table in the range of a frequency of 2–110 Hz and reviews other possible ways of vibroisolating. The paper deals with conducted experimental tests on the transmissibility of vibrations employing specific tested equipment for vibration excitation enabling to execute research facilities. The article also describes the methodology of experimental tests and presents the obtained results and conclusions of experimental analysis.
Article in Lithuanian.
Neigiamojo standumo vibroizoliacinio staliuko „MINUS K 500BM-1“ tyrimas
Santrauka. Nagrinėjamas neigiamojo standumo (angl. negative-stiffness) vibroizoliacinio staliuko „Minus K 500BM-1“ efektyvumas 2–110 Hz diapazone. Apžvelgti kiti galimi vibroizoliacijos būdai. Atlikti eksperimentiniai vibracijų perduodamumo tyrimai. Išbandyta speciali vibracijų žadinimo įranga, leidžianti atlikti numatytus bandomojo objekto tyrimus. Aprašyta eksperimentinių tyrimų metodika. Pateikti eksperimentų metu gauti rezultatai ir išvados.
Raktiniai žodžiai: standumas, naudingoji apkrova, HVAC sistemos, solenoidai, elastomerai.
Keyword : negative-stiffness, payload, HVAC systems, actuators, elastomers
This work is licensed under a Creative Commons Attribution 4.0 International License.